mirror of
https://expo.survex.com/repositories/expoweb/.git/
synced 2024-11-27 01:32:03 +00:00
119 lines
5.3 KiB
HTML
119 lines
5.3 KiB
HTML
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Strict//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-strict.dtd">
|
|
<html>
|
|
<head>
|
|
<meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1" />
|
|
<title>CUCC Expedition Handbook: Drill Battery Charging</title>
|
|
<link rel="stylesheet" type="text/css" href="../css/main2.css" />
|
|
</head>
|
|
<body>
|
|
<h2 id="tophead">CUCC Expedition Handbook</h2>
|
|
<h1>Drill Battery Charging</h1>
|
|
|
|
|
|
|
|
<h2>Instructions for charging</h3>
|
|
0) <li>If the battery has insulation tape on it (red, green, or earth) it won't
|
|
charge on the Makita standard charger and the Balance/RC charger
|
|
should be used. All batteries will charge on the RC charger, but not
|
|
as fast as on the Makita charger. Go to <a href="#RCcharge">RC charger</a>.</li>
|
|
|
|
<h3>Using Makita charger</h3>
|
|
|
|
<ol>
|
|
<li>Make sure charger is powered (flashing green LED).</li>
|
|
|
|
<li>Plug batt into Makita charger. It should start charging.</li>
|
|
|
|
<li>Look at the LEDs for status - the legend is printed on the charger.
|
|
If it flashes 'broken battery' (flashing red and gren LED) at you
|
|
after a few seconds, use the yellow (Pro-Peak Prodigy II) RC charger instead.</li>
|
|
|
|
<li>Eventually it should show '100%' (steady green LED) (in about 1
|
|
hour max). You are done.</li>
|
|
</ol>
|
|
|
|
<h3 id="RCcharge">Using Pro-Peak (or Accucell 6) RC charger</h3>
|
|
|
|
<ol>
|
|
<li>Make sure charger is powered (display lit up)</li>
|
|
|
|
<li>Connect charger to battery (either hardboard adaptor or empty
|
|
Makita base adaptor). Check polarity is correct with hardboard
|
|
adaptor.</li>
|
|
|
|
|
|
<li>Check display says 'Lion' or 'Lipo' and '14.4V' and '3A' and 'CHARGE'. Hold
|
|
down 'start/enter' button (on right). It will do a battery check.</li>
|
|
|
|
<li>If it shows '4' as the number of cells, then press 'start/enter'
|
|
again. Charging will start (fan comes on, display changes). If it
|
|
shows anything else like 'polarity reversed' or 'connection break'
|
|
then fix the connection to the battery. If it shows '3' as number of
|
|
cells it is probably knackered, but possibly can be coaxed back into
|
|
action. Find a battery expert - don't just use the charger anyway.</li>
|
|
|
|
<li>Once it beeps and says 'FULL' (flashing) then you are done (should
|
|
be less than 2 hours). Display shows number of mAh put in in
|
|
bottom right. Should be a number like 250 for each hole drilled
|
|
(between 50 and 2900 depending how discharged it was).</li>
|
|
</ol>
|
|
|
|
|
|
<h3>Can I tell if a battery is already charged?</h3>
|
|
|
|
<p>Simplest it try to charge it again and find that it says it is done
|
|
in a couple of minutes. This may waste a 'life' on batteries that
|
|
still work on the Makita charger. Checking it on the RC charger will
|
|
not waste a life. It will quickly rise to 16.4V, and the current drop
|
|
to 0.1A or so. That indicates a full pack. It will tell you so after a
|
|
while (1-5 mins).
|
|
</p>
|
|
|
|
<h3>What sort of batteries are they</h3>
|
|
|
|
<p>The drill batts are 4S2P 14.4V lithium ion packs (8 18650 cells: 4 in
|
|
series, each being a parallel pair). This means that they are charged
|
|
as 4-cell packs, to 4.1V per cell-pair. They can be charged at up to
|
|
3A rate. Battery 1 has connector wired as balance connector. No other
|
|
packs have this yet (2017). The official Makita packs use Sony SE
|
|
US18650VT (1.5Ah, 20A high-drain) cells, and we have a few with with Samsung
|
|
INR18650-13Q (1.3Ah high-drain cells). All give a reliable 2.3-2.6Ah
|
|
capacity in practice, even after 9 years expo useage. </p>
|
|
|
|
<h3>Makita charging protocol issues</h3>
|
|
|
|
<p>Makita have put very 'conservative' software in the batteries which
|
|
will stop them working on the Makita charger, even when they are in
|
|
fact fine. The monitoring board is powered off the 1st cell pair so
|
|
that one tends to get discharged more than the others when left
|
|
sitting for the 11 months of not-expo. If an unbalanced (or
|
|
over-disharged, or too-hot) pack is inserted into the makita charger
|
|
the charger and battery will do serial-coms negotiation, the charger
|
|
will refuse to charge the battery and the battery will remember this.
|
|
If you try this 3 times, the battery will mark itself bad and will
|
|
never charge again on a makita charger. Only a replacement monitoring
|
|
board can fix this (or new software if we knew how to nobble it).</p>
|
|
|
|
<p>Such batteries are normally still fine and charge on a sensible (RC
|
|
- Radio Control, because RC people are the main market for these
|
|
chargers) charger, possible after a balance charge to get the cells in
|
|
the pack in sync again. Expo has a couple of these and will be getting
|
|
more. Unfortunataly Makita don't build the 14.4V packs with balance
|
|
connections to the cells, so the PCB has to be replaced to make this
|
|
work easily for expo, which is the plan for 2018.</p>
|
|
|
|
<p>Note that the drills have no battery-voltage monitoring at all, and the
|
|
monitoring circuit is bypassed when conected to the drill (the charger
|
|
uses a different connector-pair from the drill - that's why there are
|
|
3 slots). Thus the drill can easily be used to over-discharge a
|
|
battery, so please stop drilling when it gets slow and put on a new
|
|
batt, unless it's an emergency. Drilling with an excessively-sagged
|
|
voltage is a good way to knacker the weakest cell-pair. If your battery
|
|
does get to this state, try to charge it up as soon as possible. Cells
|
|
must not be left at <2V for any length of time as they rapidly
|
|
(hours/days?) degrade to useless in this state (and that pair will
|
|
need replacing).</p>
|
|
</body>
|
|
</html>
|
|
|